xCPU | 32bit CPU 408MHz | Feature | 60K-color Resistive Touch Screen |
---|---|---|---|
Susupply Voltage | DC24V | Power Consumption | 4-6w |
Highlight | Coolmay Programmable PLC Controller,PLC Controller With HMI Display,PLC Controller With 5 Inch HMI |
DC24V Programmable PLC Controller With 5 inch HMI Display Monitor QM3G-50FH 32 bit CPU 408MHz
In the field of personalized applications, coolmay technology provides users with a PLC application platform to create high-performance industrial integration control solutions for users, saving time and cost for users, improving efficiency and enhancing corporate competitiveness.
PRODUCT DESCRIPTION of HMI PLC ALL IN ONE
Feature:
1. Super functions.PLC compatible with FX3G/FX3U/FX3S PLC.It operate fast.
2. Highly integration.The digital points are 30 inputs and 30 outputs at most.The digital output can be transistor,relay or mixed output.Analog can reach up to 16 input and 8output.It has 2PLCCOM port(Rs232and USB Port).1 downloading port on HMI
3. Support several high-speed counting and high-speed pulse.Acceleration and deceleration are independent.The total high-speed counting and pulse can not exceed 480KHz
4. 32K steps program capacity.32K power-off retentive registers.support interrupt.linear and circular interpolation.PID self-adjusting
5. Special encrvotion.Set password as 12345678 to thorouahly prevent readina dataPLC only supporls 8-bit password encryotion
6. PLC is compatible with programming software GX Developer8.86Q and GX Works2and HMl is mView software.
7. The network module can be selected accordina to customer reauirements to realize remote control More models are supported to customize if bulk order.
-
-
HMI Feature 60K colors resistive touch screen, supports portrait display Type 5"TFT Display size 108*65mm Resolution(pixels) 800*480 RAM 64MB (Please inquire if requires storing historical data) ROM NOR Flash 8MB CPU 32bit CPU 408MHz COM ports Type-C HMI download port (can download PLC program through the USB penetrating function), RS232 port Software Coolmay TPWorks HMI Programming Software PLC I/O level - Input: Passive NPN, public terminal isolated
- Transistor output: Low level NPN, COM connect to negative
- Relay output: Normally open dry contact
DO type and load - MT: 2A/point, 4A/4 point COM, 5A/12 point COM
MR: 2A/point, 5A/12 point COM
High-speed counting Single phase 6 channel 60KHz, or 2 AB 60KHz + 1 AB 10KHz, or 2 ABZ 60KHz + 1 AB phase 10KHz High-speed pulse
(Only for MT models)
8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz.
High-speed counting + high-speed pulse < 480KHz
COM port 1x TYPE-C, 1x RS232, 1x RS485 Software Compatible with GX Developer8.86 and GX WORKS 2 Service advantages
1. Production equipment
Coolmay, which has 15 years of expertise in automation solutions for various industries, has6000 square meters of production space and 10 production lines, many imported high-end smtplacement equipment and testing equipment, and its monthly output can reach 50,000 units.
2. Certification
Coolmay has passed the ISO9001 quality management system certification and the national high-tech enterprise certification. lts products have obtained a number of utility model patent certificatesand invention patents, and have repeatedly won many awards such as "Technical lnnovationAward" and "Innovative Product Award".
In addition, all Coolmay products have passed CE & RoHS certification.
3. Raw materials and accessories
The raw materials and parts used by Coolmay are the best: the CPU adopts imported 32-bitindustrial-grade chips, the PCB board with three anti-paint protection, the relays and transistorsimported from the United States, and the input and output with photoelectric isolation protection.
4. Good service
Coolmay is an original manufacturer of OEM&ODM PLC and HMl, which can meet various needsof customers. All our products have undergone 5-step strict quality control and 48 hours of aging.The products are of high quality, with a guarantee of up to 18 months and a simple return policy.
Provide Free Technical Support, learning tutorials and video tutorials.
Provide Free HMl programming Software and PLC programming software.
FAQ
1.Precautions of using PLC transistor and relay
The PLC output is a common cathode output, the theoretical value is 1A, the actual use is less than 500mA, the COM wiring is negative, please use 24V voltage, there is no voltage output when it is used as a switch. If an external relay, the relay needs an external power supply.
The relay has a contact life, the theoretical value is 30W times, and the theoretical value of the external load does not exceed 5A. Frequently, the full load current may affect the service life, and there is no voltage out.
2.Precautions of Coolmay PLC output type selection
MT: indicates the transistor output, MR: indicates the relay output, and MRT: indicates the relay transistor mixed output.
The main differences between transistor output and relay output are:
(1)The difference in current load. At present, we use a transistor with a maximum current load of 500MA, and the maximum current load of the relay is 5A (the maximum relay current of the EX2N(S)/DX2N(S) series PLC is 3A);
(2)Output power: The transistor can only be connected to the DC24V power supply , and the relay can be connected to the DC24V and AC220V power supply ;
(3)Functional characteristics: If you need to send a pulse to drive a stepper motor, you should use the transistor output or the mixed output. Also if the output switch is active, it is recommended to use a transistor output;
(4)If both the relay and the transistor are available, it is recommended to use a transistor output because the transistor has no contact life limit and the lifetime will be longer than the relay as long as the current does not exceed the limit.