Low Level NPN Transistor HMI PLC Panel 16AI 8AO Single Phase
| Brand Name: | Coolmay |
| Model Number: | QM3G-100FH-60MT |
| MOQ: | 1 unit |
| Price: | Negotiable |
| Payment Terms: | T/T, Western Union |
| Supply Ability: | 100,000 pcs per month |
NPN Transistor HMI PLC Panel
,HMI PLC Panel 16AI 8AO
,Single Phase Coolmay HMI Display
HMI PLC All In One Low Level NPN Transistor Output Single Phase Max 16AI 8AO
Precautions for PLC programming
The PLC is compatible with GX Developer8.86/GX Works2 and below. If you use other versions of software, incompatibility may occur.
When the PLC program is downloaded, there is a prompt error: Cannot specify the com port,
GX 8.86 software: Online-Transfer settings change com port;
Works 2: All targets-Change the com port in all connected targets;
If there is a communication abnormality, cable abnormality and other prompts, remove it by cutting off the power, checking the cable, checking whether the power supply is normal, or replacing the computer
![]()
Parameter: optional ferroelectric
| Display | Dimension | 275*194*36mm |
| Cutout size | 262*180mm | |
| Type | 10"TFT | |
| Feature | 60K-color resistive touch screen, supports portrait display | |
| Memory | RAM | 64MB(HMI when stores historical data, optional ferroelectric is required) |
| ROM | NOR Flash 16MB | |
| CPU | 32bit CPU 408MHz | |
| I/O | DI/DO | Max 30DI/30DO (max 28MR) |
| DI/DO level |
Input: Passive NPN, public terminal isolated Transistor output: Low level NPN, COM connect to negative; Relay output: Normally open dry contact |
|
| DO type and load | Relay MR/MOS tube, MOS tube: 2A/point, 4A/4 point COM, 5A/12 point COM; MR: 2A/point, 5A/12 point COM. | |
|
Analog I/O (optional) |
Max 16AI/8AO | |
| AI type (optional) |
Thermocouple E/E_/K/K_/S/S_/T/T_/J/J_ / PT100/ PT1000/ NTC10K/ NTC50K/ NTC100K/ 0~10V/ 0~5V/ 0~20mA/ 4~20mA/ -5V~5V/ -10V~10V / mixed |
|
| AO type (optional) |
0~10V /0~5V/ 0~20mA/ 4~20mA/ mixed/ -5~5V/ -10~10V (2AO for 1 minus voltage) |
|
| High-speed function | High-speed counting |
Single phase 6 channel 60KHz, or 2 AB 60KHz + 1 AB 10KHz, or 2 ABZ 60KHz + 1 AB phase 10 KHz |
| High-speed pulse |
8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz. High-speed counting + high-speed pulse < 480KHz |
|
| Connection | HMI | Type-B HMI download port (can download PLC program through the USB penetrating function), RS232 |
| 1 RS485 (changed from default RS232) | ||
| PLC | 1 Mini USB, 1 RS232 (program port) | |
| 1 RS485 or 2 RS485 COM ports (one is changed from the default RS232 port) | ||
| CAN (2.0A/B) port, Ethernet port, WIFI (will occupy default RS232 port) | ||
| Software | HMI | Coolmay mView HMI Programming Software |
| PLC | Compatible with Mitsubishi GX Developer 8.86 and WORKS 2 |
Advantage:
◆Military level 32 bit CPU adopted, which is faster and more adapted to industrial environment of high electromagnetic interference.
◆Special encryption, prevent illegal reading thoroughly. 8-bit encryption, 12345678 as password can thoroughly prevent reading of ladder logic program.
◆Clock supported, rechargeable battery adopted.
◆Default with 1 HMI download port, 2 PLC programming ports (RS232/MiniB USB port or Type-C), and one USB port.
◆Convenient wiring. All wiring terminals adopt 3.81 pitch pluggable terminals, which is convenient for customers to use.
◆Flexible use. More specifications and batches can be customized according to customer requirements.
◆32K program capacity, 32K retentive register, support interrupt, linear arc interpolation ,PID auto-tuning, high powerful.
◆The PLC is compatible with Mitsubishi programming software, and the HMI uses TK series human-machine interface programming software mView.
-
Cgood product!