• Shenzhen Coolmay Technology Co., Ltd.
    Juan Guevara
    muy buen trato con el vendedor y muy buena asesoria y el producto está trabajando muy bien ya tiene un año y no he tenido ningún problema
  • Shenzhen Coolmay Technology Co., Ltd.
    Obert Matetakufa
    I'm very happy with the business deal and all the support they are giving . A very good business partner
Contact Person : Sandra
Phone Number : 008619925291353
Whatsapp : +8619925291353

24VDC Positioning Industrial Control PLC 32k Steps 60KHz GX WORKS 2

Place of Origin Shenzhen
Brand Name Coolmay
Certification CE
Model Number LO2M32T
Minimum Order Quantity 1 unit
Price Negotiable
Packaging Details Packed with standard carton box
Delivery Time 3-8 working days
Payment Terms T/T, Western Union, MoneyGram
Supply Ability 100,000 pcs per month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Programming Language Ladder Diagram(LD) Program Capacity 32k Steps
CPU Digital I/O 16DI / 16DO Rated Input Voltage 24VDC
Default COM Type-C Do Type Transistor Output
Retentive Area MRAM Has No Write Limit Software Compatible With GX WORKS 2
High Light

24VDC Positioning Industrial Control PLC

,

Industrial Control PLC 32k Steps

,

60KHz Plc Control Module

Leave a Message
Product Description

Industrial Control PLC 24VDC Positioning Outputs Special Encryption GX WORKS 2

 

L02 series CPU module is a high-end application controller. L02 series CPU has built-in up to 8 axis (pulse type) positioning outputs,up to 6 groups of high-speed counter inputs, and diverse network communication options, providing users with powerful network functions. By setting program to establish various network device links. With the built-in memory card function of the L02 series CPU module, system settings can be quickly backed up or restored.

 

Parameter:

Model

LO2M32T

Programming language

Ladder diagram(LD) / lnstruction list / Sequential function chart(SFC)

Program capacity

32k steps

Storage capacity

Date (D)

[D0~D127] 128points General / [D128~D7999] 7872points Retentive / [D8000~D8511]512points Special

Expansion(R)

[R0~R22999] 23000points Support power-down retention / [R23000~R23999] 1000points Internal use

Expansion model

Max limit of 31 units: max 12 analog input/output respectively

Max l/O

FX3U mode: 512 points; FX3G mode: 256 points (the sum of input and output points)

CPU Digital I/O

16DI / 16DO

CPU analog I/O

NA

Timer T

[TO~T199] 200points 100ms General / [ [T250~T255] 6points 100ms Retentive
[T246~T249] 4points 1ms cumulative Retentive / [T256~T319] 64points 1ms General
[T200~T245] 46points 10ms General

※The 10ms timer is affected by the scan period.
lf the scan period is 12ms,the timer becomes 12ms and executes once.

16-bit counter C

[CO~C15] 16points General

32-bit counter C

[C200~C219] 20points General

[C235~C245 Single phase single counting][C246~C250 single phase double counting]

[C251~C255 Two-phase double counting]

High-speed pulse

4-axis 200KHz+4-axis 50KHz (Y0-Y3 each 200KHz; Y4-Y7 each 50KHz, total should not be over 200KHz)

High-speed counter

6 channels 60KHz

Do type

Transistor output, load maximum 500mA, low level NPN, COM connected to negative

Default COM

Type-C, RS-232, RS-485*2, Ethernet, CAN

Protocol

Programming port Modbus RTU, Modbus TCP, Modbus UDP,

freeport protocol, CAN, Ethernet/IP, BD board

Data backup function No
battery storage

Program

Flash ROM

Retentive area

MRAM has no write limit

Calendar(RTC)

Commercially available batteries CR1620(optional)

Self-diagnosis

CPU abnormalities, internal memory problems, etc

Rated input voltage

24VDC(土10%)

Software

Compatible with GX WORKS 2

 

Function Feature:

◆Adopting Military level 32 bit CPU, compatible to with FX3G/FX3U/FX3S series PLC,run faster and more adapted to industrial environment of high electromagnetic interference.

◆High speed pulse, regular as 8 channels, Y0-Y3 in 200KHz,Y4-Y7 in 100KHz (Y4-Y7 total pulse should not be over 200KHz).

◆High speed counter, regular as single phase 6 channels 60KHz or AB(Z) phase 2 channels 60KHz+ AB phase 1 channel 10KHz.

◆Special encryption, prevent illegal reading thoroughly. 8-bit encryption, 12345678 as password can thoroughly prevent reading of ladder logic program.