• Shenzhen Coolmay Technology Co., Ltd.
    Juan Guevara
    muy buen trato con el vendedor y muy buena asesoria y el producto está trabajando muy bien ya tiene un año y no he tenido ningún problema
  • Shenzhen Coolmay Technology Co., Ltd.
    Obert Matetakufa
    I'm very happy with the business deal and all the support they are giving . A very good business partner
Contact Person : Sandra
Phone Number : 008619925291353
Whatsapp : +8619925291353

1 RS232 12AI 8AO HMI PLC Combo NPN Input Public Terminal 60KHz

Place of Origin Shenzhen, China
Brand Name COOLMAY
Certification CE
Model Number QM3G-70KFH-38MR
Minimum Order Quantity 1 set
Price Negotiable
Packaging Details Carton packaging / Wooden box packaging
Delivery Time 5-8 work days
Payment Terms T/T, Western Union
Supply Ability 100,000 units per month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Type 10" TFT Feature Supports Portrait Display
RAM 64MB ROM NOR Flash 16MB
DI/DO 20DI/18DO Analog I/O (optional) Max 16AI/8AO
HMI Connection Type-B HMI Download Port PLC Connection 1 Mini USB, 1 RS232 (program Port)
HMI Software Coolmay MView HMI Programming Software PLC Software Compatible With Mitsubishi GX Developer 8.86 And WORKS 2
High Light

12AI 8AO HMI PLC Combo

,

1 RS232 HMI PLC Combo

,

60KHz PLC HMI Panel

Leave a Message
Product Description

HMI PLC Combo NPN Input Public Terminal Isolated Max 12AI/8AO

 

Features

◆Upper computer programming software compatible with Works 2/GX Developer8.86 (supports Ladder diagram and SFC language, does not support structured programming/labels).

◆Powerful, compatible with FX3G/FX3U/FX3S PLC, high processing speed.

◆Military level 32 bit CPU adopted, which is faster and more adapted to industrial environment of high electromagnetic interference.

◆Special encryption, prevent illegal reading thoroughly. 8-bit encryption, 12345678 as password can thoroughly prevent reading of ladder logic program.

◆Clock supported, rechargeable battery adopted.

◆Default with 1 HMI download port, 2 PLC programming ports (RS232/MiniB USB port or Type-C), and one USB port.

◆Support Mitsubishi programming protocol/MODBUS protocol/RS protocol/BD board protocol, easily realize PLC interconnection and communication with external devices.

◆High-speed counting, conventionally single-phase 6 channels 60KHz or AB (Z) phase 2 channels 60KHz + AB phase 1 channel 10KHz. High-speed pulse, conventionally 8 channels: Y0-Y3 is 100KHz, Y4-Y7 is 10KHz. High-speed counting+ High-speed pulse cannot exceed 480KHz; acceleration and deceleration are independent.

◆Convenient wiring. All wiring terminals adopt 3.81 pitch pluggable terminals, which is convenient for customers to use.

◆Flexible use. More specifications and batches can be customized according to customer requirements.

◆32K program capacity, 32K retentive register, support interrupt, linear arc interpolation ,PID auto-tuning, high powerful.

◆The PLC is compatible with Mitsubishi programming software, and the HMI uses TK series human-machine interface programming software mView.

 

Parameter

Display Dimension 226*163*35.6mm
Cutout size 217*154mm
Type 7"TFT
Feature 60K-color resistive touch screen, supports portrait display
Memory RAM 64MB
ROM NOR Flash 16MB
CPU 32bit CPU 408MHz
I/O DI/DO 20DI/18DO
DI/DO level

Input: Passive NPN, public terminal isolated

Relay output: Normally open dry contact

DO type and load MR: 2A/point, 5A/12 point COM.

Analog I/O

(optional)

Max 12AI/8AO
AI type (optional)

Thermocouple E/E_/K/K_/S/S_/T/T_/J/J_ / PT100/ PT1000/ NTC10K/ NTC50K/ NTC100K/

0~10V/ 0~5V/ 0~20mA/ 4~20mA/ -5V~5V/ -10V~10V / mixed

AO type (optional)

0~10V /0~5V/ 0~20mA/ 4~20mA/ mixed/

-5~5V/ -10~10V (2AO for 1 minus voltage)

High-speed function High-speed counting

Single phase 6 channel 60KHz, or 2 AB 60KHz + 1 AB 10KHz,

or 2 ABZ 60KHz + 1 AB phase 10 KHz

High-speed pulse

8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz.

High-speed counting + high-speed pulse < 480KHz

Connection HMI Type-B HMI download port (can download PLC program through the USB penetrating function), RS232
1 RS485 (changed from default RS232)
PLC 1 Mini USB, 1 RS232 (program port)
1 RS485 or 2 RS485 COM ports (one is changed from the default RS232 port)
CAN (2.0A/B) port, Ethernet port, WIFI (will occupy default RS232 port)
Software HMI Coolmay mView HMI Programming Software
PLC Compatible with Mitsubishi GX Developer 8.86 and WORKS 2
 

1 RS232 12AI 8AO HMI PLC Combo NPN Input Public Terminal 60KHz 0

 

PLC analog wiring

Two-wire system:the positive pole of the power supply is connected to the positive pole of the transmitter; the negative pole
of the transmitter is connected to the AD side; the negative pole of power supply is connected to GND,which normally it is wring
way of 4-20mA/0-20mA transmitter.
Three-wire system:the positive pole of the power supply is connected to the positive pole of the transmitter; the negative pole of the power supply and the negative pole of the signal output are the same terminal and transmitter signal output is connected to the AD terminal;
Four-wire system:the positive and negative poles of the power supply are respectively connected to the positive and negative poles of the power supply of the transmitter,and the positive and negative poles of the transmitter signal output are respectively connected to the AD and GND terminals.
The analog line of the temperature is connected to the AD terminal and the GND terminal respectively. if I is a three-wire Pt100, it needs to be connected in two lines. The GND common terminal of the analog input and output can be shared.
 
PLC anti-interference processing
1,Strong and weak currents should be separated and wired, and not common ground;
when there is strong electric interference,magnetic rings should be added on the power supply side;
and properly and effectively grounded according to the type of the chassis.
2,when the analog quantity is disturbed, 104 ceramic capacitors can be added for filtering,and a correct
and effective grounding can be performed.